论文
  您现在的位置:首页 > 科研成果 > 论文
  论文 更多内容>>
论文编号:
论文题目: Treatment of typical antibiotics in constructed wetlands integrated with microbial fuel cells: Roles of plant and circuit operation mode
英文论文题目: Treatment of typical antibiotics in constructed wetlands integrated with microbial fuel cells: Roles of plant and circuit operation mode
第一作者: Wen, Huiyang
英文第一作者: Wen, Huiyang
联系作者: 祝惠,阎百兴
英文联系作者: H. Zhu, B. X. Yan
外单位作者单位:
英文外单位作者单位:
发表年度: 2020
卷: 250
期:
页码:
摘要:

This study evaluated the removal efficiencies of sulfamethoxazole (SMX), tetracycline (TC) and their common co-existing contaminants, i.e., chemical oxygen demand (COD) and nitrogen in constructed wetlands integrated with microbial fuel cells (MFC-CWs), as affected by plant, circuit operation mode and influent antibiotic loads. The results demonstrated that MFC-CWs with plant and circuit connection exhibited the best performance in SMX and TC removal. The removal percentages for SMX and TC were 99.70-100% and 99.66-99.85% at HRT of 1 d, respectively, in MFC-CWs with plant and circuit connection when the influent SMX and TC concentrations were 5-100 mu g L-1 and 5-50 mu g L-1. The removal efficiencies of both SMX and TC were mainly enhanced by the circuit connection, compared to the plants. The presence of plant and circuit connection also accelerated the accumulation of SMX and TC in electrode layers, and the residues of both antibiotics in the anode layer were higher than in the cathode layer. Besides, closed-circuit MFC-CWs showed better COD removal performance than open-circuit MFC-CWs, irrespective of the increasing influent COD and antibiotic concentrations. The NH4+-N removal in MFC-CWs was mainly promoted by the presence of plants and decreased with increasing influent antibiotic concentrations. Additionally, the bioelectricity generation of planted MFC-CWs was better than in unplanted systems. The coulombic efficiencies in both planted and unplanted MFC-CWs decreased with increasing influent antibiotic concentrations. In summary, MFC-CWs with plant and circuit connection have potential for the treatment of wastewater containing SMX and TC. (C) 2020 Elsevier Ltd. All rights reserved.

英文摘要:

This study evaluated the removal efficiencies of sulfamethoxazole (SMX), tetracycline (TC) and their common co-existing contaminants, i.e., chemical oxygen demand (COD) and nitrogen in constructed wetlands integrated with microbial fuel cells (MFC-CWs), as affected by plant, circuit operation mode and influent antibiotic loads. The results demonstrated that MFC-CWs with plant and circuit connection exhibited the best performance in SMX and TC removal. The removal percentages for SMX and TC were 99.70-100% and 99.66-99.85% at HRT of 1 d, respectively, in MFC-CWs with plant and circuit connection when the influent SMX and TC concentrations were 5-100 mu g L-1 and 5-50 mu g L-1. The removal efficiencies of both SMX and TC were mainly enhanced by the circuit connection, compared to the plants. The presence of plant and circuit connection also accelerated the accumulation of SMX and TC in electrode layers, and the residues of both antibiotics in the anode layer were higher than in the cathode layer. Besides, closed-circuit MFC-CWs showed better COD removal performance than open-circuit MFC-CWs, irrespective of the increasing influent COD and antibiotic concentrations. The NH4+-N removal in MFC-CWs was mainly promoted by the presence of plants and decreased with increasing influent antibiotic concentrations. Additionally, the bioelectricity generation of planted MFC-CWs was better than in unplanted systems. The coulombic efficiencies in both planted and unplanted MFC-CWs decreased with increasing influent antibiotic concentrations. In summary, MFC-CWs with plant and circuit connection have potential for the treatment of wastewater containing SMX and TC. (C) 2020 Elsevier Ltd. All rights reserved.

刊物名称: Chemosphere
英文刊物名称: Chemosphere
论文全文:
英文论文全文:
全文链接:
其它备注:
英文其它备注:
学科:
英文学科:
影响因子:
第一作者所在部门:
英文第一作者所在部门:
论文出处:
英文论文出处:
论文类别:
英文论文类别:
参与作者: H. Y. Wen, H. Zhu, B. X. Yan, Y. Y. Xu and B. Shutes
英文参与作者: H. Y. Wen, H. Zhu, B. X. Yan, Y. Y. Xu and B. Shutes
地址:吉林省长春市高新北区盛北大街4888号 邮编:130102
电话: +86 431 85542266 传真: +86 431 85542298  Email: neigae@iga.ac.cn
Copyright(2002-2021)中国科学院东北地理与农业生态研究所 吉ICP备05002032号-1